Single-width Airway Module, E-miniC
For compact CO2 sidestream respiratory monitoring
The E-miniC Module is a single-width, plug-in module. The module is intended for use for patients weighing over 5 kg (11 lb) only
Features
• CO2 side-stream measurement done at the patient’s airway
• Very small and reliable measurement technology
• Inspired and end-tidal CO2 values displayed on the screen as waveforms and in numerical format
• Full numerical and graphical trends of all measured data
•Measurement of respiration rate up to 80 breaths per minute
•Fast response time
•Wide measurement range for CO2
•Adjustable high and low alarm limits for EtCO2 and FiCO2
•Manual adjustment for N2O and O2 allowed for improved CO2 measurement accuracy
•Accommodates water separation system which is lightweight, and has good tolerance for tilting
Technical specifications
General
Sampling rate 150 ±25 ml/min
Displayed values updated breath by breath
Manual O2 and N2O compensation allowed to improve CO2 measurement accuracy • When manual O2 compensation is not activated (O2 concentration 40% to 95%), CO2 reading decreases <0.3 vol%
• When the manual compensation for O2 is activated (O2 concentration 40 to 95%), the error in the CO2 reading is < 0.15 vol%
• When manual N2O compensation is not activated (N2O concentration 40 to 80%), CO2 reading increases < 0.8 vol%
• When the manual compensation for N2O is activated (N2O concentration 40 to 80%), the error in the CO2 reading is < 0.3 vol%
Non-disturbing gases
Ethanol, acetone, methane, nitrogen, water vapor: Effect on readings at 5.0 vol%: < 0.2 vol% (max)
Carbon dioxide (CO2)
EtCO2 End-tidal CO2 concentration
FiCO2 Inspired CO2 concentration
Measurement range 0 to 20 vol%
(0 to 20 kPa, 0 to 150 mmHg)
Accuracy CO2 concentration 0 to 15 vol%
±(0.2 vol% + 2 % of reading)
CO2 concentration 15 to 20 vol%
±(0.7 vol% + 2 % of reading)
Rise time < 300 ms with nominal flow
Adjustable low and high limits for EtCO2 or FiCO2
Respiration rate (RR)
Measurement range 4 to 80 breaths/min
Breath detection 1% variation in CO2 level
Accuracy ±1/min in the range
4 to 20 breath/min
±5% in the range
20 to 80 breath/min
Resolution 1/min
Adjustable low and high limits for respiration rate; alarm for apnea
Monitor compatibility
CARESCAPE modular monitors
AS/3, CS/3 and S/5 modular monitors using software L-ANE02(A), L-ICU02(A) or later versions
Performance specifications
Functional alarms Blocked sample line, water trap replacement, water trap check, low gas sample flow
Environmental specifications
Operating conditions
Temperature 10 to 40°C (50 to 104°F)
Relative humidity 10 to 95% non-condensing
Atmospheric pressure
variation 500 to 800 mmHg
(666 to 1060 mbar)
Storage conditions
Temperature -25 to 70°C (-13 to 158°F)
Relative humidity 10 to 95% non-condensing
Physical specifications
Dimensions (H x W x D) 11.2 x 3.7 x 20.9 cm
(4.4 x 1.5 x 8.2 in)
Module weight 0.4 kg (0.9 lb)